medilogFD

The 12-lead Holter ECG for a spatial heart health analysis enables assessing the full spectrum of cardiac ECG conditions. medilogFD instantaneously detects atrial fibrillation/atrial flutter based on true P-wave analysis. The optional SpO2 sensor allows for additional respiratory information.

medilogFD is the Holter ECG recorder with the holistic approach. Instantaneous detection of atrial fibrillation onset, analysis of respiratory episodes, and high-resolution HRV are just some of the exceptional features. The 12-lead Holter ECG is preferred for detailed and spatial heart analysis. Regional assessment of myocardial ischemia: distinguish anterior, septal, lateral, inferior region in the dynamic setting of everyday life. medilogFD identifies the origin of ectopic beats, whether they are from the left or right ventricle. This SCHILLER Holter is superior in identifying abnormal heartbeats that start in the right or left atrium.

Features

  • 12-lead Holter ECG allows assessing the full spectrum of cardiac ECG conditions
  • Instantaneous atrial fibrillation/atrial flutter detection based on true P-wave analysis thanks to a superior resting ECG-grade 128,000Hz sampling rate on 12 leads
  • Optional SpO2 sensor for additional respiratory information
  • Multifactor signal check based on impedance, amplitude and amount of noise
  • High-contrast colour display for easy operation. Live ECG preview: 3 channels shown at a time, all 12 can be scrolled through
  • Microphone to record patient ID. In an anonymous start, a voice recording is a must to prevent patient mix-up.
  • Easy-to-clean carrying case
  • Eco-friendly: runs on an internal rechargeable battery, or, if needed, on normal AAA batteries for fast turnaround times
  • medilogFD completes your medilog line-up with medilogAR (3-lead Holter ECG, up to 14 days runtime) and medilog DARWIN2 (high-end ECG analysis software)
designed_manufactured_eu

SCHILLER reserves the right to make changes in design, specifications and features shown, or discontinue the product described at any time without notice or obligation. Images may be representative. Device availability in your market is subject to regulatory approval.

Bluetooth for recording configuration and SpO2

Bluetooth for recording configuration and SpO2

128’000 Hz sampling rate

128’000 Hz sampling rate

SpO2 optionally

SpO2 optionally

Dual-battery concept for 120 h recording time

Dual-battery concept for 120 h recording time

Videos

This content is displayed to you via YouTube.
This allows YouTube to collect personal data. You can find details on this in YouTube's terms of use.

Any questions? We’re happy to help!

Software & Connectivity


  • Heart rate variability (HRV) and the autonomic nervous system

    Fire of Life
    Read more

  • Hospital level communication solution

    SCHILLER Server
    Read more

  • The SCHILLER Data Management System

    SEMA Workstation
    Read more